Dell R220 physical appliance details

Included with your Dell™ PowerEdge™ R220 appliance, you will receive a chassis with front panel and back panel features, and rails for racking.

Figure 1. Dell PowerEdge R220 Rack Server

The information below is excerpted from the Dell PowerEdge R220 Systems Hardware Owner's Manual and the Dell PowerEdge R220 Technical Guide, available on the Dell Web site.

Technical specifications

Feature Technical Specifications
Processor
Processor type

Intel Core i3-4130 and Core i3-4330 processorproduct family

Intel Pentium processor G3430 and G3420

Intel Celeron processor G1820

Expansion bus
Bus type PCI Express Generation 3
Expansion slots using riser card One half-height, full-length x16 link
Memory
Architecture 1600 MT/s or 1333 MT/s unbuffered Error Correcting Code (ECC) DIMMs
Memory module sockets Four 240-pin
Memory module capacities
UDIMM 4GB (single-rank) and 8 GB (dual-rank)
Minimum RAM 4GB
Maximum RAM 32 GB
Drives
Hard drives Up to two 3.5 inch Enterprise Class and Entry Class SATA, SAS, or Nearline SAS hard drives, or Up to two 2.5 inch SAS, SATA, or Nearline SAS hard drives
Optical drive

One optional slim 12.7 mm SATA DV-DROM or DVD+/-RW drive

NOTE: DVD devices are data only.

Connectors
Back
NIC Two 10/100/1000 Mbps
Serial 9-pin, DTE, 16550-compatible
USB Two 4-pin, USB 3.0-compliant
Video 15-pin VGA
Front
USB Two 4-pin, USB 2.0-compliant
Video 15-pin VGA
Internal
USB One 4-pin, USB 2.0-compliant

Environmental

NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.

Temperature
Maximum Temperature Gradient (Operating and Storage) 10 °C/h (50 °F/h)
Storage Temperature Limits –40 °C to 65 °C (–40 °F to 149 °F)
Temperature (continuous operation)
Temperature Ranges (for altitude less than 950 m or 3117 ft) 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on the equipment.
Humidity Percentage Range 10% to 80% Relative Humidity with 29 °C (84.2 °F) maximum dew point.
Relative humidity
Storage 5% to 95% RH with 33 °C (91 °F) maximum dew point. Atmosphere must be non-condensing at all times.
Maximum vibration
Operating 0.26 G rms at 5 Hz to 350 Hz for 15 minutes (all operation orientations).
Storage 1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested).
Maximum shock
Operating One shock pulse (one pulse each side of the system) of 31 G for 2.6 ms in the operational orientation.
Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 32 G faired square wave pulse with velocity change at 270 inches/second (686 centimeters/second).
Maximum altitude
Operating 3048 m (10,000)
Storage 12,000 m (39,370 ft).
Operating altitude de-rating
≤ 35 °C (95 °F) Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft).

Particulate contamination

NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of the customer.

Air filtration

NOTE: Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.

Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.

NOTE: Air entering the data center must have MERV11 or MERV13 filtration.

Conductive dust

NOTE: Applies to data center and non-data center environments.

Air must be free of conductive dust, zinc whiskers, or other conductive particles.

  • Air must be free of corrosive dust.
  • Residual dust present in the air must have a deliquescent point less than 60% relative humidity.

Gaseous contamination

NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.

Copper Coupon Corrosion Rate <300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
Silver Coupon Corrosion Rate <200 Å/month as defined by AHSRAE TC9.9.

Dimensions and weight

Unit Measurement
Height 1.66” (42.4 mm) (without ear/bezel)
Width 17.09” (434 mm) (without ear/bezel)
Depth 15.52” (394.3 mm) (without ear/bezel)

Specific measurements (corresponding with figure 2)

Dimension Measurement
Xa (width with rack latches) 482.0 mm
Xb (width without rack latches) 434.0 mm
Y (height) 42.4 mm
Za (depth with bezel) 35.0 mm
Za (depth without bezel) 20.1 mm
Zb (depth without power supply and bezel) 390.0 mm
Zc (depth with power supply) 394.3 mm

Figure 2. Dell R220 PowerEdge dimensions

 

Front panel features and indicators

Figure 3. Dell PowerEdge R220 front panel features and indicators

 

The following table explains the Dell R220 front panel features and indicators. See Figure 3 for reference.

Item Indicator, button, or connector Icon Description
1 Power-on indicator, power button

The power-on indicator lights when the system power is on. The power button controls the power supply output to the system.

Note On ACPI-compliant operating systems, turning off the system using the power button causes the system to perform a graceful shutdown before power to the system is turned off.

2 NMI button

Used to troubleshoot software and device driver errors when using certain operating systems. This button can be pressed using the end of a paper clip.

Use this button only if directed to do so by qualified support personnel or by the operating system's documentation.

3 Video connector

Allows you to connect a VGA display to the system.

4 Health indicator

If the system is on, and in good health, the indicator lights solid blue.

The indicator blinks amber if the system is on or in standby, and any error exists (for example, a failed fan or hard drive).

5 Hard-drive indicator The indicator blinks green to indicate hard-drive activity.
6 Electrical indicator

The indicator blinks amber if the system experiences an electrical error (for example, voltage out of range, or a failed power supply or voltage regulator).

See the System Event Log or system messages for the specific issue. Re-seat the power supply by removing and reinstalling it. If the problem persists, see Getting help.

7 Temperature indicator

The indicator blinks amber if the system experiences a thermal error (for example, a temperature out of range or fan failure). Ensure that none of the following conditions exist:

  • A cooling fan is removed or has failed.
  • System cover, cooling shroud, EMI filler panel, memory-module blank, or back-filler bracket is removed.
  • Ambient temperature is too high.
  • External airflow is obstructed.

See Getting help.

8 System status indicator  

Lights blue during normal system operation.

Lights amber when the system needs attention due to a problem.

  • See the System Event Log or system messages for the specific issue.
  • Invalid memory configurations can cause the system to halt at startup without any video output.

See Getting help.

5 System identification button

The identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pressed, the system status indicator on the front and the back of the system flashes until one of the buttons is pressed again.

Press to toggle the system ID on and off.

If the system stops responding during POST, press and hold the system ID button for more than five seconds to enter BIOS progress mode.

To reset iDRAC (if not disabled in the iDRAC Settings option) press and hold the button for more than 15 seconds.

10 USB connectors(2) Allow you to connect USB devices to the system. The ports are USB 2.0-compliant.
11 System service tag  

A slide-out label panel that allows you to record system information such as Service Tag, NIC, MAC address, and so on as per your need.

12 Optical drive (optional)  

One optional slim SATA DVD-ROM drive or DVD+/-RW drive.

Back panel features and indicators

Figure 4. Dell PowerEdge R220 back panel features and indicators

The following table explains the Dell R220 back panel features and indicators. See Figure 4 for reference.

Item Indicator, button, or connector Icon Description
1 iDRAC6 Enterprise port (optional)

Dedicated management port for the optional iDRAC6 Enterprise card.

2 VFlash media slot (optional)

Connects an external SD memory card for the optional iDRAC6 Enterprise card.

3 Serial connector

Connects a serial device to the system.

4 PCIe expansion card slot   Allows you to connect one low-profile PCI Express expansion card.
5 Video connector

Allows you to connect a VGA display to the system.

6 eSATA Allows you to connect additional storage devices.
7 USB connectors (2)

Allow you to connect USB devices to the system. The ports are USB 3.0-compliant.

8 Ethernet connectors (2)

Two integrated 10/100/1000 Mbps NIC connectors.

9 System status indicator   Indicates the status of the system. Lights blue during normal system operation. Lights amber when the system needs attention due to a problem.
10 System identification button

The identification buttons on the front and back panels can be used to locate a particular system within a rack. When one of these buttons is pressed, the system status indicator on the front and the back of the system flashes until one of the buttons is pressed again.

Press to toggle the system ID on and off.

If the system stops responding during POST, press and hold the system ID button for more than five seconds to enter BIOS progress mode.

To reset iDRAC (if not disabled in the iDRAC Settings option) press and hold the button for more than 15 seconds.

11 Power supply  

250 W AC power supply.

12 Retention clip  

Secures the power cable.

 

Rails

ReadyRails™ static rail system provides tool-less tool-less mounting in 19”-wide, EIA-310-E compliant square hole and unthreaded round hole racks via the ReadyRails mounting interface. The rails also offer tooled mounting support for 4-post threaded and 2-post (Telco) racks for added versatility.

Figure 5. Dell PowerEdge R220 static rails

 